Elite Loss Single Mode MPO optical adapter / Xim daj SM ULL MTP fiber optic coupler
MPO optical adapter / MTP fiber optic coupler Kev piav qhia
+ MPO optical adapter / MTP fiber optic coupler yog lub adapter (tseem hu ua coupler) uas siv los txuas MPO / MTP poj niam lub cev cable thiab MPO / MTP txiv neej lub cev cable lossis MPO / MTP poj niam lub cev cable thiab MPO / MTP txiv neej module (MPO / MTP txiv neej rau LC module).
+ Nws yog siv rau MPO-8, MPO-12, MPO-16, MPO-24, MPO-32, MPO-48 connector.
+ MPO optical adapter / MTP fiber optic coupler siv hauv MPO / MTP high density patch panel thiab FTTA multi-function box.
+ MPO optical adapter / MTP fiber optic coupler yog ib lub adapter, thiab nws tsuas yog poj niam xwb. Lub MPO / MTP lub cev cable siv rau MPO / MTP adapter xav tau los nrog ib sab poj niam (tsis muaj tus pin) thiab ib sab txiv neej (nrog tus pin)
+ MPO optical adapter / MTP fiber optic coupler muaj 2 hom:
- Hom sib txawv (Tus yuam sij nce mus rau Tus yuam sij nqis): siv rau tus qauv Hom A lub cev cable.
- Hom sib dhos (Tus yuam sij nce mus rau Tus yuam sij nce): siv rau tus qauv hom B lub cev cable.
+ MPO optical adapter / MTP fiber optic coupler yog nrog flange, tuaj yeem kho qhov adapter rau hauv daim phiaj vaj huam sib luag.
+ MPO optical adapter / MTP fiber optic coupler siv:
Cov Lus Qhia Tshwj Xeeb
| Hom Txuas | MPO/MTP | Lub cev Style | SC hom Simplex |
| Hom Fiber | Ntau hom Ib hom xwb | Xim Lub Cev | Ib hom UPC: dub Ib hom APC: ntsuab Ib hom ULL: daj Multimode: dub OM3: dej hiav txwv OM4: xim av |
| Kev poob ntawm kev ntxig | ≤0.15dB | Kev sib yuav ruaj khov | 500 zaug |
| Flange | Nrog flange Tsis muaj flange | Kev Taw Qhia Tseem Ceeb | Key Up - Key Up Tus yuam sij rau saum - Tus yuam sij rau hauv qab |
Daim Duab Loj:
Cov ntawv thov
+ MPO Breakout & Fan-Out Solutions
+ Kev sib txuas lus fiber optic passive
+ Lub kaw lus network ntawm cov tuam txhab lag luam
+ MPO module / MTP module
+ MPO siab ntom thaj vaj huam sib luag / MTP ntom thaj vaj huam sib luag
+ Cov Khoom Siv Kuaj
+ Cov cuab yeej xa cov ntaub ntawv ceev ceev
+ I-cloud data center
+ AI & Kev Siv Computer Zoo (HPC)
+ Chaw khaws cov ntaub ntawv sib txuas lus
+ FTTA sab nraum zoov ntau lub thawv
+ Kev Txuas Cable Ntawm Chaw Khaws Cov Ntaub Ntawv
Cov yam ntxwv
•Txhawb nqa qhov ceev txog li 40 GbE/100 GbE.
•Lub cuab yeej txuas thawb/rub daim ntawv teeb tsa/tshem tawm nrog ib sab tes.
• 8, 12, 16, 24, 32, 48-fibers MTP/MPO connectors.
•Muaj ib hom thiab Multimode.
•Kev ntsuas qhov loj me siab.
•Kev sib txuas ceev thiab yooj yim.
•Cov tsev yas sib dua thiab ruaj khov.
•Kev tsim cov khoom sib txuas ib daim ua rau lub zog sib txuas siab tshaj plaws thaum txo qis cov khib nyiab.
•Xim Aqua, Violet xaiv tau.
•Siab hnav tau.
•Zoo rov ua dua.
Kev thov ib puag ncig:
| Kub ua haujlwm | -20°C txog 70°C |
| Kub cia khoom | -40 ° C txog 85 ° C |
| Av noo | 95% RH |